- As all ovens of the series are fitted with an alternating fan motor (clockwise and anticlockwise rotation), there is no need for the fan to rotate in any particular d i r ec t i o n . Simply verify, when commissioning the appliance, that the fan is balanced and rotates freely. Warning: the 20 x GN 1/1 and 20 x GN 2/1 models are equipped with two motors.
- When making the electrical connection you need to take care that the neutral pin of the terminal block corresponds to the neutral wire of the supply line. If this connection is not made correctly, the burners will not be able to operate. This error is signalled by the electronic circuit board.
- Check also that the neutral registers zero potential when tested. If not, the fault already described in point three of this section will occur. In this eventuality, consult the installer of the building’s electrical system.
- Ethernet connection
Use at least a category 5 network cable for the data connection. The Ethernet connection is located on the lower right- hand side of the appliance.