Naboo - How do you connect the oven to the water supply?

Appliances are intended to be permanently connected to the water mains.

WATER PRESSURE

La pressione dell’acqua nella rete deve essere compresa fra 200 e 500 kPa, come già riportato nel capitolo “Dati tecnici”. Qualora la pressione fosse superiore, interporre a monte dell’apparecchio un riduttore di pressione.

 

WATER HOOKUP TO SUPPLY THE STEAM GENERATOR (IF PRESENT) AND VAPORIZER

Direct steam ovens: The vaporizer requires softened cold or hot (max 50°C) water depending upon the characteristics.

Ovens with steam generators: The vaporizer and steam generator do not require a softener and can use cold or hot (max 50°C) water.

The water attachment is R 3/4”. The water hose must be provided by the installer and must be in compliance to IEC 61770. Do not reuse pre-existing or used hoses. A water shut-off valve must be installed upstream of the oven.

B• Cold water supply input

D• Softened water supply input (up to a max. temperature of 50°C)

 

FOR MODELS: 061-101-062-102-054-084

 

FOR MODELS: 201-202-154

The connection to the mains water is located on the bottom right side of the appliance.
To access the connections, remove the bottom right-hand side panel

 

FOR MODELS: 161-134

The connection to the mains water is located on the rear right side of the appliance.

 

WATER SPECIFICATIONS

The characteristics of the water must come within the limits given below, in order to prevent both corrosion, which is extremely damaging for the appliance, due to supplying water that is too softened or too aggressive, and scaling in the oven and in the water system in the case of supplying water that is too hard.

Hardness: between 6° and 9° fH

PH:    greater than 7.5

Chlorides: less than 30 ppm

These values are important for ensuring that the water used by the appliance is suitably treated!

 

WATER CONNECTION FOR STEAM CONDENSATION

Cold water must be hooked up for steam condensation. The water attachment is R 3/4”. The water hose must be provided by the installer and must be in compliance to IEC 61770. Do not reuse pre-existing or used hoses. A water shut-off valve must be installed upstream of the oven.
It is advisable not to use a treatment system that causes carbonate hardness less than 6 °fH as water having these characteristics may be aggressive and corrosive, thus shortening the service life of the appliance.

UK only:
WRAS approval IRN 160. To be carried out by the installer: An approved double check valve or some other no less effective backflow prevention device shall be fitted at the point of connection between the supply and the fitting.

The use of sodium ion exchangers (commonly known also as salt softener) is not recommended.

 

Recommended water composition limits:

 

Water hardness parameters conversion table