Sapiens - How do you solve the error message “A06 no gas alarm”?

A06 Gas shortage alarm warn that gas is not detected; as consequence unit stops temporary burners, cooking and show the message. 

This message does not necessarily require the intervention of a technician; the causes of the failure can be external.

Description

The gas pressure switch PG prevents activation of the burners in case of inadequate pressure in the system. In case of activation, the combustion may be inadequate and cause damage to things and people.

Warning

Always check static and dynamic pressure to the valve inlet; dynamic pressure has to be G20>16mbar G30>25 mbar

Reset

Message reset automatically when pressure rise. In case of defective PG possible to shorcircuit, temporary, input 13 – 14 on I/O PCB

Checks

Perform following checks: 
- Check the gas tap opening 
- Check proper gas pressure. 
- Check proper setting of pressure switch. If necessary set it or if defective change it.