Puff - How do you replace the detergent container?

CHECK LEVEL DETERGENT/DESCALER

 

If there is not enough detergent to run the selected wash cycle, a pop- up window will appear on the display telling you to visually check the detergent/descaler level (1).

 

Open the oven door and the small door under the cooking chamber and check the quantity of detergent/descaler in the cartridge (2).

 

   

If the cartridge/canister is empty, press “BACK” (4) and replace it by following the instructions in the paragraph “REPLACING THE DETERGENT/DESCALER CARTRIDGE” (5) before starting the wash cycle.

 

REPLACING THE DETERGENT/DESCALER CARTRIDGE/CANISTER

 PERSONAL PRECAUTIONS

Avoid exposing skin and eyes by wearing suitable protective clothing and gloves, cat. I (EN 374 standard).

Do not inhale product vapour or powder.

 

NOTE:

The “COMBICLEAN” detergent cartridge has a YELLOW coloured cap

 

Open the oven door and small door under the cooking chamber, unscrew the top of the empty cartridge and remove it (100% recyclable).

     

Position the new cartridge in its dedicated housing in the oven.
IMPORTANT: Wait for the liquid to stabilise before opening the cap.
Take care not to invert the COMBICLEAN and CALFREE CARTRIDGES.

Remove the top of the new cartridge.

Insert the cap with the extraction system ensuring that the clear extraction pipe is facing the front of the cartridge as shown in the figure.

Close the top carefully.

Put the cartridge back in is slot and close the small door and the oven door.

 

 

On the oven display, press the “SET MAX” key which corresponds to the COMBICLEAN or CALFREE that has been replaced.

 

 

The indicator now displays the tank as completely full, select the desired wash cycle to start the washing procedure.

 

WARNINGS

See the safety data sheets of the cleaning products.

In case of skin (or hair) contact with the detergent: immediately remove all contaminated garments. Wash the skin thoroughly under running water with soap. If irritation persists, seek medical advice”.

In case of contact with eyes: Remove contact lenses, if present and easy to do. Wash eye immediately with plenty of water. Seek medical advice.

In case of inhalation: Move the person in question away to a uncontaminated area. If breathing stops, perform artificial ventilation and seek immediate medical assistance if necessary.

In case of ingestion: Seek immediate medical assistance. Drink as much water as possible. Do not induce vomiting unless expressly authorised by medical personnel. Show the doctor the safety data sheet of the product ingested which can be found the starter kit for all devices.