Neo24hours - How do you connect the blast chiller to the water supply?

Connect the machine to mains able to supply water with the following characteristics:

  • is drinkable;
  • has a maximum temperature of 30 °C;
  • has a maximum conductivity of 150 μS/cm;
  • has a maximum hardness of 17,8 °f (French degrees) that corre- spond to 10°dH (German degrees);
  • has a pressure value between 150 and 330 kPa (250 kPa is rec- ommended).

If the input water pressure is:

  • lower than the indicated value (150kPa), use a pump with appropriate capacity (minimum flow rate 300 l/h)
  • higher than the indicated value (330kPa) use a pressure Damages to components due to limestone deposit are not cov- ered by the warranty.