Naboo - How do you solve the error message “A80 Combiclean flow alarm”?

A80 CombiClean flow alarm (only for appliances with CDSS and CDSV option) warns of an anomaly in CombiClean consumption.

This message does not necessarily require the intervention of a technician; check the presence of product in the tank.

Description

The CombiClean flow sensor does not generate pulses when the detergent pump is activated.
There is therefore no liquid in the CombiClean suction circuit.

Warning: check that the CombiClean tank contains the product.

Reset

The error is automatically reset when fluid flow in the circuit is restored by activating a washing cycle.

Checks

Check the following:

  • Presence of CombiClean in the tank.
  • Correct positioning of the cap.
  • Product suction circuit; any cracks or bad connections can lead to air being sucked in because it is less dense than the product.
  • Operation of the detergent pump.
  • Electrical connections between flow meter and control board.
  • Control board connections and its operation.