A110 Door open alarm occurs if the door is open during the cooling phase.
This message does not necessarily require the intervention of a technician.
Description
Door open alarm during the cooling cycle.
Reset
Set date and time from the Customer Setting menu.
Checks
Perform following checks:
- Check that the door is really closed
- Check door alignment -
- Check P12 (polarity)
- Check door micro switch position / operation
- Check board