A09 Washing alarm warns that cabinet temperature exceeded max temperature (during washing. The appliance will stop the washing; switch off and let cool down the unit.
This message requires the intervention of an authorized technician; causes of the fault must be investigated as per prescriptions.
Description
The cabinet probe SC, during washing, detect a temperature over the maximum allowed 120°C/248°F.
Reset
Message cannot be confirmed; switch off the unit to cool down.
Checks
Perform following checks:
- Check contact of contactors C2 and C3 or SSR stay open when unit is in standby. If they stay closed change contactor.
- Check if fan wheel really spins.
- Check water supply, S1 and humidification pipe - Check probe SC and PCB.