A31 Generic alarm inverter 1 warns of a problem with the inverter that controls the chamber fan.
As consequence unit stop any function.
This message requires the intervention of an authorized technician; causes of the fault must be investigated as per prescriptions.
Description
The inverter 1 has registered a generic error.
Warning
Inverter capacitors can be charged, before any action disconnect the power supply. Always check the conditions around the inverter and the motor (presence of water leaks, visible damage, etc.).
Reset
Error is automatically reset after the cause resolution.
Checks
Perform the following checks:
- Check the inverter
- Check wiring inverter/motor
- Chech for meccanical blockage fan/motor
- Check inverter settings