Sapiens - How to replace the descaler cartridge/tank?

Image_131-png

 

REPLACING THE CALFREE DESCALER CARTRIDGE/TANK

If when you recall the wash procedure, the message “Check CALFREE level” appears on display 15, check the detergent level:

Counter top model: open the oven door and the hatch located under the oven's cooking chamber and check the amount of detergent in the cartridge.

Floor-standing model: check the quantity of detergent in the tank.

 

If the cartridge/tank is empty, replace it following the instructions in the following paragraph, otherwise confirm the “OK” message by pressing knob 16 to start the wash.

The “CALFREE” descaler cartridge has a GREEN coloured cap.


COUNTER TOP MODEL - REPLACING THE CARTRIDGE:

Unscrew the cap of the empty cartridge and remove it.

Position the new cartridge in its dedicated housing in the oven.

IMPORTANT: Wait for the liquid to stabilise before opening the cap.

Remove the cap from the new cartridge and insert the tube with the GREEN cap, making sure that the tube is facing the front part of the cartridge, and close the cap well.

Turn knob 16, select “New” and confirm by pressing knob 16 to continue with the wash procedure.

 

FLOOR-STANDING MODEL - REPLACING THE TANK:

 Unscrew the cap of the empty tank and remove it.

Reposition the tank.

IMPORTANT: Wait for the liquid to stabilise before opening the cap.

Remove the cap from the tank and insert the tube with the GREEN cap, making sure that the tube is on the bottom of the tank, and close the cap well.

Turn knob 16, select “New” and confirm by pressing knob 16 to continue with the wash procedure.