Oracle - Panels

Top panel

To access components you must remove at first the top panel.

There are three screws on the back which can be used also to fix the container on the top

two screws on the front.

Once removed the screws pull from the back.

 

Side panels

To remove side panel remove the two screws on the back.

Once removed the screws slide back side panel.

 

Rear flap

To remove the rear flap remove the two screws.

 

Rear panel

To remove the rear panel remove the four screws

 than pull the panel

 

High voltage protection shield

To remove the rear flap.

Remove the two screws on the top

the two on the sides

than pull up the shield

 

Door removing

 

To remove the door

open the door (90°)

insert two pins/rivets on the holes on the hinge than pull up the door and rotating inside the door extract hinges from housing.

See in the picture how fixed on the body.

Hinge fixing point.

Warning: removing the door means adjust/check door microswitches and micorwaves leakages