Puff - Instructions for switching on and using after a long period of inactivity

After a long period of non-use, it is advisable to contact your trusted help service to arrange a visit in order to check whether any maintenance is required.

If you wish to act independently, proceed as follows, r emembering that the manufacturer recommends the annual inspection of the appliance.

a)    Flush the water tubes to prevent any deposits or residue from clogging the solenoid valves and then reconnect the supply tubes.
b)    If a Brita filter is installed, check the date of installation (the filter must be replaced within a year, otherwise the active carbons will deteriorate and cause the potential spread of bacteria), flush the filter and if necessary replace it according to the instructions in the user manual.
c)    Check the connection/reconnect the drain tube.
d)    Connect the electrical power supply and energize the appliance
e)    Turn the appliance on by pressing the on button for 5 seconds
f)    Insert/connect the cans of chemical product
g)    Check that there are no leaks from the water connections
h)    If a message appears, take note or photograph the display and get in contact with your trusted help service
i)    Check whether a software update is available; this can be done from the display if the appliance is connected to the internet, otherwise the software version will be available for download from the manufacturer’s portal.
j)    Run a cleaning programme to prime the cleaning system pumps and check for any water leaks.