Oracle - How do you solve the error message A93?

The message occurs after 10 seconds of waiting and informs that there is a calibration problem or a failure of the port interlock microswitch.

As a result the drive stops all functions and displays the message.

This message requires the intervention of an authorized technician; the causes of the breakdown must be sought as per the prescriptions of the house.

DESCRIPTION

The cooking was started by the operator but, after 10 seconds, the contact door B3 is still open (IN 47-48). At the same time the monitor input of the Magnetrons (IN 4) detects the phase and the power board is not powered.

WARNING

A imperfect closing of the door or an incorrect adjustment of the microswitches can be caused by wear, incorrect installation of the door or by lifting the appliance from the door handle.

CHECKS

To restore proper operation check:

  • That the door is properly closed and seal the cabinet
  • That B3 is open when the door is open and closed when the door is closed
  • Feeding and proper connection of all phases
  • That the cycle count is less than 100,000
  • That the right and left hinges are properly hooked and adjusted
  • That the BM, B1 and B2 microswitches are correctly adjusted hot and cold