Oracle - How do you solve the error message A08?

A08 High board temperature alarm warns that PCB temperature exceeded 75°C/167°F.

The appliance will stop any activity; switch off and let cool down the unit.

This message does not necessarily require the intervention of a technician; the causes of the failure can be external. 

Description

Temperature sensor on PCB detect a temperature over the maximum allowed temperature.

Reset

Message cannot be confirmet; switch off the unit and wait for cooling down. Remove root cause of overtheating

Checks

Check the following:

  • Check the status of the air filter; clean it if needed
  • Check correct installation of the appliance (ventilation and nearby heat sources)
  • Check that the cooling fans are working properly and that the flows are correct.
  • Check door alignment
  • Check temperature probe on pcb.