Oracle - How do you solve the error message A07?

A07 High board temperature warns that PCB temperature reached 70°C.

The message can be confirmed and possible to proceed even if it is advisable to stop and let unit cool down.

This message does not necessarily require the intervention of a technician; the causes of the failure can be external. 

Description

Temperature sensor on PCB detect a temperature near to the maximum allowed temperature 70°C/158°F.

Warning

Check filters, cooling fans and proper air flow Reset Message can be confirmed pressing on the message bar but it’s mandatory to remove root cause of the overheating.

Checks

Check the following:

  • Check the status of the air filter; clean it if needed
  • Check correct installation of the appliance (ventilation and nearby heat sources)
  • Check that the cooling fans are working properly and that the flows are correct.
  • Check door alignment - Check temperature probe on pcb.