Neo24hours - How do you connect the blast chiller drain?

 

Cleansing water is collected in a tank which is under the machine.

We recommend you connect the drain to a maximum 200 cm long hose (not supplied) and lead it to a grate in the floor or wall drain pipe, to avoid empting the tank too frequently.

The discharge of the humidification system, blue, shall be con- nected to a floor discharge point. In the absence of this, by moving the pipe previously indicated inside the technical compartment and fixing it to the washing drain pipe, it is possible to discharge the water in the special collection tank, which must be emptied every 4 hours.

The drain pipe must have the following characteristics:

  • is of trap type;
  • has a minimum inclination of 4%;
  • has an air gap* of at least 25 mm;
  • does not have clamps;
  • has a diameter not under that of the drain pipe joint.