Naboo - How to resolve error message “A07 High board temperature“?

A07 High board temperature warns that PCB temperature reached 70°C.
The message can be confirmed and possible to proceed even if it is advisable to stop and let unit cool down.

This message does not necessarily require the intervention of a technician; the causes of the failure can be external.

Description 

Temperature sensor on PCB detect a temperature near to the maximum allowed temperature 70°C/158°F.

Warning

Check cooling fans and proper air flow.

Reset

Message can be confirmed pressing on the message bar but it’s mandatory to remove root cause of the overheating.

Checks

Check the following:
  • Check correct installation of the appliance (ventilation and nearby heat sources).
  • Check that the cooling fans are working properly and that the flows are correct.
  • Check door gasket for integrity and door aligment.
  • Check temperature probe on pcb.